The N2 FLO comes with a purity analyzer and pressure regulator to allow for real-time monitoring of the nitrogen purity. It has a nitrogen storage tank for ease of use, allowing you to avoid the buffer tank.  It features a digital control system that can be interfaced with external systems. If the nitrogen used is less than the amount produced, the generator automatically goes into energy-saving stand-by mode. A humidity and oil particle analyzer mounted on the suction line prevents impurities from passing through, protecting the operation of the generator and quality of the gas produced. E941 food purity option allows for different calibrations in order to meet specific customer needs. 

Efficient

Air consumption is minimized thanks to the FAST PURITY® system. Enhanced efficiency allows for higher purity.

Easy Installation

Electronic control and pre-set programs allow for a fast and easy installation process. 

Hands-Off Operation 

The generator is able to work unattended and independently 24 hours a day, 365 days a year. 

Custom Nitrogen Purity 

The nitrogen purity can be set according to customer and application requirements. 

STANDARD FEATURES

  • Claind's PSA Fast Purity technology

  • Oxygen analyzer and pressure regulator included standard

  • No buffer needed -- one vessel is both the buffer and consumption nitrogen reservoir

  • Fast and easy installation thanks to electronic control with pre-set programs

  • Can safely work unattended and independently 

  • Automatically goes into stand-by mode if the production flow exceeds consumption 

  • Nitrogen purity can be set according to application requirements 

  • Digital control board allows data sharing through protocols such as MODBUS, MQTT, and HTTP

 

SPECS

Instrument Name FLO
Technology Employed

Claind's Pressure Swing Adsorption (PSA) Fast Purity Process

Inlet Air Specifications

Min Air Pressure 6.5 bar

Max Air Pressure: 13 bar

Quality: dry, clean, exhalation free

Must meet ISO 8573-1 Class 1.4.1 specifications

Nitrogen Outlet Pressure

1.5 bar lower than the inlet pressure

Moisture

 -50°C dew point ATP 

Electrical Supply 115 V +/- 10% 60 Hz
230 V +/- 10% 50 Hz 
Power Rating

50W

Protection Index   

IP20

Noise  


≤ 60 dB (at 1 m from generator)

Operating Temperature  5 ÷ 40°C
Dimensions 

Height:  46.5" (118cm)

Width: 15.7" (40cm)

Depth: 31.5" (80cm)

Weight 

FLO 1: 203lbs (92 kg)
FLO 2: 249lbs (113kg)
FLO 3: 295lbs (134kg)
FLO 4: 342lbs (155kg)

 

Amy & David CTA

 

SPECS

Model Outgoing Nitrogen Flow at 8.5 bar, CMS 20°C [L/min]
99.999% 99.99% 99.9% 99.5% 99% 98% 97%
N2 FLO 1 3 6 15 25 33 40 46
N2 FLO 2 8 13 30 48 60 76 88
N2 FLO 3 11 20 43 71 88 111 130
N2 FLO 4 16 28 61 96 120 151 176

 