• There are no suggestions because the search field is empty.

SOLUTIONS

Claind Laboratory Generators

MAXI
Nitrogen Generator

DESCRIPTION

The N2 MAXI comes with a purity analyzer and pressure regulator to allow for real-time monitoring of the nitrogen purity. It has a nitrogen storage tank for ease of use, allowing you to avoid the buffer tank.  It features a digital control system that can be interfaced with company IT systems. If the nitrogen used is less than the amount produced, the generator automatically goes into energy-saving stand-by mode. A humidity and oil particle analyzer mounted on the suction line prevents impurities from passing through, protecting the operation of the generator and quality of the gas produced. E941 food purity option allows for different calibrations in order to meet specific customer needs. 

Efficient

Air consumption is minimized thanks to the FAST PURITY® system. Enhanced efficiency allows for higher purity.

Easy Installation

Electronic control and pre-set programs allow for a fast and easy installation process. 

Hands-Off Operation 

The generator is able to work unattended and independently 24 hours a day, 365 days a year. 

Custom Nitrogen Purity 

The nitrogen purity can be set according to customer and application requirements. 

STANDARD FEATURES

  • Claind's PSA Fast Purity technology

  • Oxygen analyzer and pressure regulator included standard

  • No buffer needed -- one vessel is both the buffer and consumption nitrogen reservoir

  • Fast and easy installation thanks to electronic control with pre-set programs

  • Can safely work unattended and independently 

  • Automatically goes into stand-by mode if the production flow exceeds consumption 

  • Nitrogen purity can be set according to application requirements 

  • Digital control board allows data sharing through protocols such as MODBUS, MQTT, and HTTP

 

SPECS

Instrument Name MAXI
Technology Employed

Claind's Pressure Swing Adsorption (PSA) Fast Purity Process

Inlet Air Specifications

Min Air Pressure 6.5 bar

Max Air Pressure: 13 bar

Quality: dry, clean, exhalation free

Must meet ISO 8573-1 Class 1.4.1 specifications

Nitrogen Outlet Pressure

1.5 bar lower than the inlet pressure

Moisture

 -50°C dew point ATP 

Electrical Supply 115 V +/- 10% 60 Hz
230 V +/- 10% 50 Hz 
Power Rating

50W

Protection Index   

IP20

Noise  


≤ 60 dB (at 1 m from generator)

Operating Temperature  5 ÷ 40°C
Dimensions 

Height: 81.7" (207.5 cm)

Depth: 46" (117 cm)

Width: MAXI 1: 24.4" (62 cm)
MAXI 2: 40.5" (103 cm)
MAXI 3: 56" (142 cm)
MAXI 4: 71.6" (182 cm)

Weight 

MAXI 1: 1609 lbs (730 kg)
MAXI 2: 3086 lbs (1400 kg)
MAXI 3: 4519 lbs (2050 kg)
MAXI 4: 5952 lbs (2700 kg)

 

Amy & David CTA

 

SPECS

Model Outgoing Nitrogen Flow at 8.5 bar, CMS 20°C [L/min]
99.999% 99.99% 99.9% 99.5% 99% 98% 97%
N2 MAXI 1 103 150 311 518 651 828 931
N2 MAXI 2 206 300 623 1,035 1,311 1,648 1,850
N2 MAXI 3 310 450 935 1,553 1,965 2,483 2,780
N2 MAXI 4 413 600 1,246 2,070 -- -- --

 