• There are no suggestions because the search field is empty.

SUPPORT / ARTICLES

Preparing Samples for GC-MS/MS Analysis

Common sample preparation techniques for GC-MS/MS include various forms of extraction and concentration. Nitrogen blowdown is a popular concentration process used to evaporate solvents ahead of GC-MS/MS to concentrate analytes. This approach uses a stream of nitrogen gas to evaporate solvents from a sample. The nitrogen gas is directed over the surface of the liquid sample, accelerating solvent evaporation without heating the sample excessively. This helps to concentrate the analytes and remove volatile impurities.

Mass Spectrometry Sample Preparation Guide
Chromatography Sample Preparation Guide

How Nitrogen Blowdown Aids GC-MS/MS Sample Preparation

  • Sample Concentration:

- Concentrates analytes by removing large volumes of solvent, which is especially useful when dealing with dilute samples.
- Ensures that the final extract is in a suitable volume for injection into the GC-MS/MS system, improving detection limits and sensitivity.

  • Solvent Exchange:

- Used to exchange the solvent of a sample extract to one that is more compatible with GC-MS/MS analysis.
- For instance, a sample initially extracted in a high-boiling solvent might be exchanged to a more volatile solvent to ensure efficient transfer and separation in the GC column.

  • Removal of Volatile Impurities

- Helps to remove unwanted volatile components that might interfere with the GC-MS/MS analysis, ensuring a cleaner and more accurate analytical result.

Advantages of Preparing GC-MS/MS Samples With Nitrogen Blowdown

- Non-Destructive: The gentle nature of nitrogen blowdown minimizes the risk of thermal degradation of sensitive analytes.

- Efficiency: It allows for rapid concentration and solvent removal, making the sample preparation process quicker and more efficient.

- Scalability: Suitable for various sample sizes, from small volumes to larger preparative scales.

Procedure and Considerations for Blowdown of GC-MS/MS Samples

Procedure: 

- Sample Placement: The sample is placed in a vial or tube
- Nitrogen Introduction: A stream of nitrogen gas is directed over the surface of the liquid sample.
- Evaporation: The solvent evaporates, leaving behind the concentrated analytes.
- Reconstitution (if needed): The concentrated residue can be reconstituted in a smaller volume of a more GC-compatible solvent.

Practical Considerations

- Control of Gas Flow: Adjusting the nitrogen flow rate is critical to avoid splashing or losing sample material.
- Temperature Management: While the process is often conducted at room temperature, slight heating may be used to enhance evaporation for less volatile solvents, but care must be taken to avoid analyte degradation.
- Vessel Design: The design of the evaporation vessel and nitrogen delivery system should minimize cross-contamination and maximize evaporation efficiency.

Typical Uses of GC-MS/MS

  • GC-MS/MS in Environmental Analysis: 

    Concentrating trace environmental pollutants from water or soil extracts

→ Discover: Why test tube evaporators belong in any environmental lab

Pollutant Detection:

- Persistent Organic Pollutants (POPs): GC-MS/MS is used to detect and quantify POPs such as polychlorinated biphenyls (PCBs), dioxins, and furans in soil, water, and air samples.
- Polycyclic Aromatic Hydrocarbons (PAHs): PAHs, resulting from incomplete combustion processes, are monitored in environmental matrices using GC-MS/MS.
- Volatile Organic Compounds (VOCs): VOCs, including benzene, toluene, ethylbenzene, and xylene (BTEX), are commonly analyzed in air and water samples.

Biomonitoring:

- Human Exposure Assessment: GC-MS/MS is used to analyze biomarkers of exposure to environmental pollutants in biological samples such as blood, urine, and tissue.
- Wildlife Monitoring: The technique helps in assessing the exposure of wildlife to contaminants, aiding in ecological risk assessments.

Water Quality Monitoring:

- Pesticide Residues: Detection of pesticide residues in surface water, groundwater, and drinking water.
- Pharmaceuticals & Personal Care Products (PPCPs): Analysis of PPCPs in wastewater and surface water to study their environmental fate and impact.

→ Discover: Environmental sample preparation for EPA method 8270

Soil & Sediment Analysis:

- Hydrocarbons: Detection of hydrocarbon contamination from oil spills and industrial activities.
- Heavy Metals: Although GC-MS/MS is not directly used for metals, it can analyze organometallic compounds and provide indirect assessment of metal pollution through related organic compounds.

→ Discover: Preparing soil samples for EPA methods 8081 and 8082

Air Quality Monitoring:

- Ambient Air Monitoring: Measurement of VOCs and semi-volatile organic compounds (SVOCs) in ambient air.
- Indoor Air Quality: Analysis of pollutants in indoor environments, such as homes and workplaces, to assess exposure to harmful chemicals.

  • GC-MS/MS in Forensic Toxicology:

    Concentrating biological samples for drug and poison detection

Drug Screening & Confirmation:

- Drugs of Abuse: GC-MS/MS is used to detect and confirm the presence of drugs of abuse such as opioids, cocaine, amphetamines, cannabinoids, and synthetic drugs in biological samples.
- Prescription Medications: Analysis of therapeutic drugs and their metabolites to investigate potential overdose or poisoning cases.

→ Discover: Solvent Evaporator Prepares Thousands of Samples for Drug Screening

Postmortem Toxicology:

- Cause of Death Investigations: Identification and quantification of toxic substances, including drugs, alcohol, and poisons, in postmortem samples to determine the cause of death.
- Toxicological Screenings: Comprehensive screening for a wide range of substances in tissues, blood, urine, and other fluids collected during autopsy.

DUID (Driving Under the Influence of Drugs):

- Drug Impairment: Detection of drugs in blood or urine samples from individuals suspected of driving under the influence of drugs.
- Legal Evidence: Providing confirmatory evidence for the presence of controlled substances in forensic investigations related to traffic offenses.

Poisoning Cases:

- Accute Poisoning: Identification of toxic agents such as pesticides, industrial chemicals, and natural toxins in suspected poisoning cases.
- Chronic Exposure: Analysis of biomarkers indicating long-term exposure to toxic substances.

  • GC-MS/MS in Food & Beverage Testing:

    Removing solvents after extracting residues from food products

Pesticide Residue Analysis:

- Detection of Pesticides: GC-MS/MS is used to detect and quantify pesticide residues in fruits, vegetables, cereals, and other food products. It ensures compliance with regulatory limits and safety standards.
- Multi-Residue Methods: Capable of simultaneously analyzing multiple pesticide residues in a single run, making it highly efficient for routine monitoring.

Mycotoxin Analysis: 

- Fungal Toxins: Identification and quantification of mycotoxins such as aflatoxins, ochratoxin A, and fumonisins in grains, nuts, dried fruits, and beverages like wine and beer.
- Food Safety: Ensures that food products are safe for consumption by detecting toxic compounds produced by molds.

Flavor & Fragrance Analysis:

- Aroma Compounds: GC-MS/MS is used to characterize volatile and semi-volatile compounds responsible for the aroma and flavor profiles of food and beverages.
- Quality Control: Ensures the consistency and quality of flavors in products like coffee, tea, spices, and essential oils.

Food Adulteration & Authenticity:

- Detection of Adulterants: Identifies adulterants such as melamine in dairy products, synthetic dyes in spices, and illegal additives in food.
- Verification of Authenticity: Confirms the authenticity of high-value products like olive oil, honey, and wine by detecting fraudulent components.

Contaminant Detection: 

- Environmental Contaminants: Analyzes contaminants such as polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and dioxins in food products.
- Packaging: Detects contaminants that migrate from packaging materials into food, ensuring the safety of packaged food.

→ Discover: Effective solvent removal for PCB analysis

Nutritional Analysis: 

- Fatty Acid Profiling: Analyzes the fatty acid composition of oils, fats, and food products to determine their nutritional value.
- Vitamins & Additives: Detects and quantifies vitamins, preservatives, and other food additives.

  • GC-MS/MS in Pharmaceutical Analysis

    Preparing drug formulations and metabolites for GC-MS/MS

Drug Development & Formulations:

- Impurity Profiling: Detection and quantification of impurities and degradation products in drug formulations, ensuring the safety and efficacy of pharmaceuticals.
- Stability Testing: Monitoring the stability of drugs under various conditions by identifying and quantifying degradation products.

Pharmacokinetics & Pharmacodynamics:

- Drug Metabolism Studies: Analysis of drug metabolites in biological samples to understand the metabolic pathways and the pharmacokinetic properties of new drugs.
- Bioavailability & Bioequivalence: Quantifying drugs and their metabolites in biological fluids to study their absorption, distribution, metabolism, and excretion (ADME).

→ Discover: Batch evaporator prepares samples ahead of GC-MS for cancer research

Quality Control & Assurance: 

- Content Uniformity: Ensuring uniform distribution of the active pharmaceutical ingredient (API) in formulations.
- Residual Solvent Analysis: Detection and quantification of residual solvents in pharmaceuticals to comply with regulatory guidelines.

Therapeutic Drug Monitoring:

- Quantitative Analysis: Precise quantification of therapeutic drugs in blood, plasma, or serum to optimize dosing regimens and monitor patient compliance.
- Drug Interaction Studies: Analysis of drug interactions by quantifying multiple drugs and their metabolites in biological samples.

Biomarker Discovery & Validation:

- Biomarker Analysis: Identification and quantification of biomarkers for disease states or therapeutic response, aiding in the development of personalized medicine.

Nitrogen blowdown is an essential step in the sample preparation workflow for GC-MS/MS, ensuring that samples are concentrated, clean, and ready for accurate and sensitive analysis.

Stay up-to-date with
the latest news &
announcements

Contact Us

If you need support from one of our technicians, please fill out our Contact Help Support form and we will respond as quickly as possible! For all other enquiries, please use this general contact form.

 

USA 888.838.7300
Other 978.838.7300
978.838.2786